Pressure loss from an old capped pipe under the landing
The property
A 1930s semi where a combination boiler replaced the old cylinder and loft tank, and the cylinder's heating pipes were capped off under the landing boards.
The problem
Every couple of days the boiler wanted more water, though its engineer had passed it. A leak sealer had made no difference, and no radiator looked wet.
How we found it
Isolating the upstairs circuit showed it losing pressure. No warm water reaches a capped end, so the thermal camera was no use; tracer gas fed into the circuit rose through the landing boards instead.
The outcome
At the mark, one lifted board revealed a corroded cap. We cut back the spare pipe and sealed it on that visit, priced on its own, and the boiler stopped losing water.